HPLC Column, Bidentate C8, 4um, 4.6mm ID x 100mm Length, 100A. Cogent TYPE-C Brand. 1 EA.
Additional Info:
The 40008‑10P Cogent Bidentate C8™ HPLC Column is an analytical reversed‑phase column designed for methods where short (50 mm) columns do not provide sufficient resolution, but full long‑format columns are unnecessary. Built on Cogent TYPE‑C™ silica hydride technology, this column delivers excellent selectivity, faster equilibration, and extremely robust column lifetime compared with conventional silica‑based C8 columns.
The stationary phase consists of an aliphatic C8 hydrocarbon chain bonded via two direct silicon–carbon bonds (bidentate attachment) to a silica hydride surface. This non‑traditional chemistry produces a phase that is more hydrophobic than standard C8 columns, yet less hydrophobic than Bidentate C18™, making it ideal when C18 retention is excessive but stronger retention than conventional C8 is required. Unlike typical C8 phases, this column can also retain select hydrophilic compounds if desired.
The 100 mm column length increases plate count and separation efficiency compared to 50 mm formats, improving resolution of closely eluting compounds while maintaining reasonable run times. The column is also stable at very low pH (below pH 2) with no damage, significantly expanding method‑development flexibility.
Why Choose the 4.6 × 100 mm Bidentate C8™ Format
This column size is commonly selected when:
50 mm columns provide insufficient resolution
C18 columns are overly retentive or slow
Additional separation of closely eluting analytes is required
Standard analytical flow rates and system hardware are preferred
The 100 mm length provides a practical balance between resolution and run time, while TYPE‑C™ silica hydride chemistry ensures fast equilibration and long column life.
Key Features
Cogent TYPE‑C™ Silica Hydride Technology
Non‑traditional reversed‑phase surface chemistry
Reduced silanol activity and secondary interactions
Faster equilibration than conventional silica‑based C8 columns
Extremely robust and reproducible column performance
Bidentate C8™ Bonding
Two‑point attachment via direct Si–C bonds
Balanced hydrophobic retention
Alternative selectivity when C18 is overly retentive
Resolution‑Focused Analytical Geometry
4.6 mm ID × 100 mm length
Higher resolving power than 50 mm formats
Compatible with standard analytical flow rates
Broad Method Compatibility
Stable at very low pH (below 2)
Compatible with aqueous‑rich mobile phases
Suitable for aggressive and unconventional analytical methods
Typical Applications
Analytical HPLC requiring increased resolution
Situations where C18 retention is excessive
Alternative reversed‑phase selectivity
Method development and optimization
Low‑pH and aqueous‑rich mobile‑phase methods